Aller au contenu

An Anti-Infective Polymer Coating to Reduce Surface Transmission of Pathogens on Personal Protective Equipment

  • par garon@biomomentum.com

Mya Sharma; Gurpreet Randhawa; Fei Xu; Evelyn Cudmore; Todd Hoare
Polymer, Volume 328, 2025, 128428, ISSN 0032-3861, Published: 23 May 2025

https://doi.org/10.1016/j.polymer.2025.128428

1 citation · 1 en 2025–2026

Les titres, résumés et légendes des publications sont présentés en anglais.

Abstract:

Face masks are vital in protecting individuals from respiratory viruses but can serve as a source of infection if improperly used or re-used. Herein, we report anti-infective polymer coatings comprised of anti-fouling poly(oligoethylene glycol methacrylate) (POEGMA) functionalized with hydrazide groups for promoting adhesion and a quaternary ammonium compound (QAC) and/or grafted ciprofloxacin as the anti-infective component. The polymers could be functionalized to the surface of spunbonded polypropylene used for face masks using a simple aqueous dip-coating process. The QAC-functionalized coatings demonstrated a 2.0 log reduction against Staphylococcus aureus, a 1.5 log reduction against Escherichia coli, and a 0.8 log reduction against Pseudomonas aeruginosa after five hours of contact time; combination coatings containing both QAC and ciprofloxacin enabled a 2.1 log reduction against S. aureus, a 4.1 log reduction against E. coli, and a 7.3 log reduction against P. aeruginosa. In parallel, the masks maintained their key mechanical properties as well as remained in full compliance with the ASTM standards for barrier face coverings in terms of breathability and particulate filtration efficacy. Thus, this coating strategy offers potential to reduce the risk of infection from mask wear or reuse.

Keywords:

Poly(oligoethylene glycol methacrylate); Quaternary ammonium compounds; Ciprofloxacin.

Utilisation des équipements

Le Mach-1 Mechanical Tester a servi aux essais de traction de polypropylène non tissé filé-lié utilisé dans les masques, sans revêtement ou avec un revêtement polymère. Des éprouvettes en forme d’haltère ont été étirées, et le module de Young a été déterminé à partir de la portion linéaire de la courbe contrainte–déformation pour comparer les propriétés mécaniques des différentes conditions.

Matériaux (2)

Configurations de test (2)

Découvrez la recherche en pratique