Luli Li; Marc Masen
Journal of the Mechanical Behavior of Biomedical Materials, Volume 155, 2024, 106574, ISSN 1751-6161
https://doi.org/10.1016/j.jmbbm.2024.106574
7 citations · 5 en 2025–2026
Les titres, résumés et légendes des publications sont présentés en anglais.
Abstract:
A full understanding of the material properties of skin tissue is crucial for exploring its tribo-mechanical behaviour. It has been widely accepted that the mechanical behaviour of skin tissue for both small and large deformations can be accurately described using a hyperelastic model, such as the one developed by Ogden. However, obtaining these Ogden parameters for in-vivo skin by in-vivo experiments no matter the indentation or suction tests is a significant challenge. The mathematical model used to describe the material behaviour during the test should consider not only the material nonlinearity but also the geometrical confinement of the tissue, the large deformations induced, and the fact that the specimens are relatively thin. A range of contact models is available to describe the contact behaviour during the indentation test. However, none of them can be used for hyperelastic materials with small thickness under large deformations. Simultaneously explaining material nonlinearity and geometric nonlinearity, either through theoretical equations or numerical calculations, poses a significant challenge. In this research, we propose a pragmatic method to obtain Ogden parameters for in-vivo skin tissue by combining experimental indentation results and numerical simulations. The indentation tests were used to obtain the force-indentation depth curves, while the numerical simulations were used to obtain the strain fields. The method assumes the material behaviour of specimens can be linearized in each small deformation increment, and the contact model developed by Hayes can be applied to accommodate each increment. Then, the linear elastic behaviour in each increment can be described by the elastic modulus E which were obtained using Hayes model, and the principal stresses in each increment were subsequently obtained using Hooke's law. By combining all stress fields, overall stress-strain curves can be constructed, from which the hyperelastic Ogden parameters can be obtained. A second numerical simulation of the hyperelastic indentation was then performed using the obtained Ogden parameters, allowing a comparison of the experimental and simulated relationships between force and indentation.
Keywords:
Skin tissues; Material properties; Indentation test; Ogden; Contact model.
Utilisation des équipements
Le Mach-1 Mechanical Tester a réalisé des indentations sphériques sur des échantillons de substitut tissulaire Syndaver afin d’obtenir des courbes force–profondeur d’indentation pour une méthode associant expériences et simulations numériques visant à estimer les paramètres d’Ogden. L’épaisseur locale était mesurée par rapport au porte-échantillon à chaque point d’essai. Les courbes mesurées étaient corrigées pour tenir compte des variations de détection du contact initial.
Matériaux (1)