Skip to content

Electroconductive cardiac patch based on bioactive PEDOT: PSS hydrogels

  • by garon@biomomentum.com

Erwan Sauvage; Justin Matta; Cat‐Thy Dang; Jiaxin Fan; Graziele Cruzado; Fabio Cicoira; Géraldine Merle
J Biomed Mater Res. 2024; 1-10. First published: 30 April 2024

https://doi.org/10.1002/jbm.a.37729

11 citations · 9 in 2025–2026

Abstract
Engineering cardiac implants for treating myocardial infarction (MI) has advanced, but challenges persist in mimicking the structural properties and variability of cardiac tissues using traditional bioconstructs and conventional engineering methods. This study introduces a synthetic patch with a bioactive surface designed to swiftly restore functionality to the damaged myocardium. The patch combines a composite, soft, and conductive hydrogel-based on (3,4-ethylenedioxythiophene):polystyrene-sulfonate (PEDOT:PSS) and polyvinyl alcohol (PVA). This cardiac patch exhibits a reasonably high electrical conductivity (40 S/cm) and a stretchability up to 50% of its original length. Our findings reveal its resilience to 10% cyclic stretching at 1 Hz with no loss of conductivity over time. To mediate a strong cell–scaffold adhesion, we biofunctionalize the hydrogel with a N-cadherin mimic peptide, providing the cardiac patch with a bioactive surface. This modification promote increased adherence and proliferation of cardiac fibroblasts (CFbs) while effectively mitigating the formation of bacterial biofilm, particularly against Staphylococcus aureus, a common pathogen
responsible for surgical site infections (SSIs). Our study demonstrates the successful development of a structurally validated cardiac patch possessing the desired mechanical, electrical, and biofunctional attributes for effective cardiac recovery. Consequently, this research holds significant promise in alleviating the burden imposed by myocardial infarctions.
KEYWORDS
Cardiac patch, conducting polymers, hydrogel, PEDOT:PSS, PVA.

Equipment used

The Mach-1 Mechanical Tester performed electromechanical tensile tests of PEDOT:PSS hydrogels using tensile grips with electrical contacts.

Materials (3)

Test configurations (2)

See Research in Action

Explore case studies

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.