Skip to content

Normal Human Synovial Fluid Exhibits Stable Hyaluronic Acid and Proteoglycan 4 Levels Across Age and Sex

  • by garon@biomomentum.com

Lisa Yamaura; Jessica May Corpuz; Joshua Mang; Roman Krawetz
Osteoarthritis and Cartilage Open, 2026, 100864, ISSN 2665-9131, Published: 20 August 2026

https://doi.org/10.1016/j.ocarto.2026.100864

0 citations · 0 in 2025–2026

Abstract

Objective

Hyaluronic acid (HA) and proteoglycan 4 (PRG4) are the primary lubricants in synovial fluid (SF), critical to its function and overall joint health. SF composition and lubricating ability has been primarily investigated in the context of disease; however, baseline ranges in normal SF remain unclear. This study aimed to quantify PRG4 and HA concentrations and evaluate lubrication performance in human SF without any joint pathology.

Methods

SF was obtained from 33 cadaveric donors, with samples collected bilaterally in seven donors. Mean donor age was 60 ±14 years and 51.5% were female. Concentrations of HA and PRG4 were quantified and SF lubrication under static and dynamic fiction conditions was assessed. Sex differences, age correlations, and intra-individual variability in biochemical and frictional properties were analyzed.

Results

HA ranged from 0.44 to 10.13 mg/mL (mean: 2.66 ±2.05 mg/mL), while PRG4 levels ranged from 183.51 to 303.25 μg/mL (mean: 251.15 ±32.16 μg/mL). Neither lubricant correlated with age (HA: rs=0.03, p=0.88; PRG4: r=0.12, p=0.52) or sex (both p>0.5), nor showed intra-individual differences (both p>0.40). Mean static friction (0.63 ±0.08) exceeded dynamic friction (0.48 ±0.04), and both were independent of age, sex, and HA and PRG4 levels (all p>0.2).

Conclusion

Baseline concentrations of HA and PRG4 and SF lubrication properties in normal SF were independent of age and sex, with no significant association between lubricant composition and function. These findings provide a reference for normal SF lubricant composition and lubrication function and will aid in the understanding of SF lubrication dysregulation in disease states.

Equipment used

Biomechanical Analysis

Boundary lubrication testing was performed using a rotational frictional assay adapted from Larson et al., who evaluated paired cartilage explants under compression and rotation using a BOSE ElectroForce 3200 mechanical tester (Figure 1).14 In the present study, the Mach-1 mechanical tester (V500csst; Biomomentum, Laval, QC) was fitted with a custom 6.8 mm diameter 3D printed resin tip that made contact with SF applied directly to the Mach-1’s 316L stainless steel platform. The tip was printed using flexible 80A resin (Formlabs; Somerville, MA), which provides firmness and rubber-like deformability that approximates dense articular cartilage, while withstanding bending, flexing, and compressive forces through repeated cycles, supporting reproducibility over multiple tests.

*For full experimental details, please refer to the original publication.

Materials (2)

Test configurations (1)

See Research in Action

Explore case studies

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.