Abstract

Oral diseases, such as periodontitis, remain a major global concern due to their high incidence and significant morbidity. The principal drivers are bacterial overgrowth and associated inflammation. Bioactive glass of the 45S5 Bioglass® composition (BG) is known for its remineralising, osteogenic and antibacterial effects via ion release, but its application has been limited in oral environments. In this study, a photocurable GelMA hydrogel was developed as a carrier matrix for BG (1–15% w/v) to obtain synergy between the adhesive properties of the GelMA and the bioactivity of the glass. Incorporation of 10% w/v BG improved ultimate tensile strength (97 kPa) compared to pure GelMA (58 kPa) and reduced swelling by 18%. The composites showed ~60% higher adhesive strength on collagen sheets than GelMA alone. Tensile bonding strengths reached 54 kPa on collagen sheets and 23 kPa on tooth sections. Lap-shear adhesive strengths were 44 kPa on collagen and 18 kPa on implant metal. In vitro studies confirmed the composite’s biocompatibility with dental pulp stem cells and antibacterial activity against Escherichia coli and methicillin-resistant Staphylococcus aureus. Overall, the GelMA/BG composite presents a multifunctional platform for dental remineralisation with promising mechanical, adhesive and antibacterial performance.

Keywords

Bioactive glass; GelMA adhesive; composite; dental remineralisation; antimicrobial activity.

Equipment used

The Mach-1 Mechanical Tester was used for tensile testing of dumbbell-shaped pure GelMA and GelMA/bioactive-glass hydrogel specimens. Elastic modulus was calculated from the initial linear region of the stress–strain curves. Compression testing was performed separately with an ElectroForce 5500, not the Mach-1.

Materials (2)

Test configurations (3)

See Research in Action

Explore case studies

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.