A Driller-Tipped Guidewire Design with Combined Magnetic Navigation and Drilling Motion

  • by garon@biomomentum.com

Li Zhang; Tiantian Xu; Mingxue Cai; Moqiu Zhang
Research on Medical Robotics Technology. Springer, Published: 02 August 2026

https://doi.org/10.1007/978-981-95-8204-4_6

0 citations · 0 in 2025–2026

Abstract
The endovascular intervention has been widely used to treat occlusive peripheral vascular disease (PVD). However, the current procedure has concerns such as low successful rate, undesired trauma, and radiation exposure. This chapter proposes a robotic solution to mitigate these limitations. A miniature magnetic driller-tipped guidewire (MDG) is designed, which performs (1) controllable bending under directional magnetic fields to navigate in complex vasculature and (2) mechanical drilling under rotating magnetic fields to pass through clogged regions. An integrated actuation system is adopted for magnetic control and ultrasound (US) imaging in a large workspace. A control framework composed of the preoperative and intraoperative stages is developed, which internally coordinates all system modules, addresses noisy US imaging, and provides convenient operation. Demonstrations under an optical camera verify the flexible steering ability and effective unclogging motion of the MDG. Furthermore, US image-monitored in vitro experiments validate the overall hardware platform and control strategy. The designed MDG realizes dual objectives, including controllability at bifurcations and penetrability at clots. The introduced US imaging modality largely reduces radiation hazards in conventional catheterization. This chapter studies the intervention of the MDG under electromagnetic field navigation and US imaging guidance. The proposed workflow has the potential to improve operational safety and clinical outcomes of the occlusive PVD treatment.

Equipment used

The available abstract describes a magnetic driller-tipped guidewire combining directional steering and drilling, with optical demonstrations and ultrasound-monitored in vitro experiments. It does not specify mechanical test specimens, force measurements, or a role for the Mach-1 Mechanical Tester. A Biomomentum equipment-use protocol cannot be verified from this excerpt.

Materials (1)

See Research in Action

Explore case studies

Report a problem with this page

Your email is used only to follow up on this report.

Screenshots (optional)

Click this area and paste a screenshot, or drag files here. Up to 3 PNG, JPEG or WebP images; 5 MB per image. Hide confidential information first.

Please do not include passwords or customer information. Reports and screenshots are private.